9,2

Scientific Research

The secret for best clinical practice

Cruciate ligament: information, symptoms, diagnosis and treatment. Meniscus: Kniespecialist RPA Janssen is topspecialist in behandeling van meniscus in de knie.
Read more →

Associate Professor Knee Reconstruction

On NOvember 1, 2019, RPA Janssen...

Read more →

e/MTIC symposium TU/e

RPA Janssen MD PhD visits the Symposium Technology meets Value-Based Health Care. This...

Read more →

Two new publications

RPA Janssen MD PhD is co-author of 2 new peer reviewed publications this month in Knee...

Follow me!

Remain up to date with all the latest knee facts via Facebook, Twitter and other social networks


Validation of Simendo Knee Arthroscopy Virtual Reality Simulator

Validation of Simendo Knee Arthroscopy Virtual Reality Simulator

Heijden vd L, Janssen RPA, Steen der M, Reijman M, Tuijthof G
Arthroscopy. 2019 Aug;35(8):2385-2390

Abstract

PURPOSE: 

To determine the face and construct validity as well as educational value and user-friendliness of the Simendo knee arthroscopy virtual reality simulator.

METHODS: 

Sixty participants were recruited and equally divided into novices (0 arthroscopic procedures), intermediates (1-59 arthroscopic procedures), and experts (60 or more arthroscopic procedures). Participants were excluded if they had previously trained with the studied simulator. Construct validity, that is, the ability to discriminate between different levels of expertise, was examined by a navigation task. All participants were asked to perform 5 navigation trials within 10 minutes. Face validity, educational value, and user-friendliness were examined by questionnaires before and after the navigation trials. Face validity is the subjective impression of how closely the simulation replicates the real environment.

RESULTS: 

The novices were significantly slower than the intermediates in the first (P < .001) and the third (P = .031) trial. The novices were significantly slower than the experts in all trials (P = .016), except for the fifth (P = .054). The experts were significantly faster than the intermediates in every trial except for the fourth (P = .069). Median task time for the fifth trial was 63 seconds (44-80 seconds) for novices, 58 seconds (46-80 seconds) for intermediates, and 41 seconds (33-55 seconds) for experts. Ninety-two percent of all participants agreed that the simulator can be used to train for surgical inspection, and 95% indicated sufficient user-friendliness.

CONCLUSIONS: 

Based on the results, this knee simulator can be applied to train the basic arthroscopic hand-eye coordination skills at the start of resident education programs. Further testing is necessary to determine whether the skills are retained.

CLINICAL RELEVANCE: 

The simulator is partly validated, which contributes to training of basic arthroscopic skills without compromising patient safety.


← Back to publications

 

RPA Janssen, MD PhD 
Orthopaedic Surgeon
Orthopaedic Associates Eindhoven Greater Area
Orthopedic Center Máxima
Máxima Medical Center (MMC)

Visiting adress MMC Eindhoven:
Ds. Th. Fliednerstraat 1
Ingang Zuid
5631 BM  Eindhoven
The Netherlands 
(outpatient clinic and surgery)

Visiting adress MMC Veldhoven:
De Run 4600
5504 DB  Veldhoven
The Netherlands
(Outpatient clinic)

Mail adress:
Postbus 90052
5600 PD  Eindhoven
The Netherlands

Tel. 0031 (0)40 88 88 600
(Call center Orthopedie)

Fax: 0031 (0)40 88 85 938
www.rpajanssen.com 

Links:
Orthopaedic Associates Eindhoven Greater Area
Máxima Medical Center
Orthopaedic Center Máxima
 

RPA Janssen YouTube
RPA Janssen Twitter
RPA Janssen Facebook
RPA Janssen LinkedIn
RPA Janssen weblog




s2